STIBINE | ICSC: 0776 |
Antimony hydride Antimony trihydride Hydrogen antimonide (cylinder) SbH3 Molecular mass: 124.8 RTECS # WJ0700000 ICSC # 0776 UN # 2676 EC # 051-003-00-9 |
TYPES OF HAZARD/ EXPOSURE |
ACUTE HAZARDS/ SYMPTOMS |
PREVENTION |
FIRST AID/ FIRE FIGHTING |
FIRE |
Extremely flammable.
Cylinder may explode in heat of fire.
Gives off irritating or toxic fumes (or gases) in a fire.
|
NO open flames, NO sparks, and NO smoking.
|
Shut off supply; if not possible and no risk to surroundings, let the fire burn itself out; in other cases extinguish with
water spray.
|
EXPLOSION |
Gas/air mixtures are explosive.
Risk of fire and explosionon contact with ozone or concentrated nitric acid.
|
Closed system, ventilation, explosion-proof electrical equipment and lighting.
|
In case of fire: keep cylinder cool by spraying with water.
Combat fire from a sheltered position.
|
EXPOSURE |
|
AVOID ALL CONTACT!
|
IN ALL CASES CONSULT A DOCTOR!
|
|
Cough.
Headache.
Laboured breathing.
Nausea.
Sore throat.
Weakness.
Wheezing. Weak and irregular pulse. Haemoglobinuria.
|
Ventilation, local exhaust, or breathing protection.
|
Fresh air, rest.
Refer for medical attention.
|
|
ON CONTACT WITH LIQUID: FROSTBITE.
|
Cold-insulating gloves.
|
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.
|
|
Redness.
|
Eye protection in combination with breathing protection.
|
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
|
|
|
|
|
SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
Evacuate danger area!
Consult an expert!
Ventilation.
(extra personal protection: self-contained breathing apparatus).
|
Fireproof.
Cool.
|
Xn symbol R: 20/22 S: (2) Note: A UN Hazard Class: 2.3 UN Subsidiary Risks: 2.1 |
||
SEE IMPORTANT INFORMATION ON BACK | ||||
|
|
STIBINE | ICSC: 0776 |
I M P O R T A N T D A T A |
| |||
PHYSICAL PROPERTIES |
| |||
ENVIRONMENTAL DATA |
|
|||
N O T E S | ||||
Explosive limits are unknown in literature, although the substance is combustible and has a flash point <61░C.
Depending on the degree of exposure, periodic medical examination is indicated.
The relation between odour and the occupational exposure limit cannot be indicated.
|
ADDITIONAL INFORMATION | |||||
|
|
||||
|
|